123456789101112131 Type
TVR VAV terminal unit
 
2 Acoustic cladding
No entry: none
With acoustic cladding
 
3 Material
No entry required: galvanised sheet steel
P1Powder-coated RAL 7001 (silver grey)
A2 Stainless steel construction
 
4 Duct connection

No entry: push-fit, suitable for ducts according toEN 1506; with groove for optional lip seal
FLFlanges both ends (not for TVR-D-P1)  
5 Nominal size [mm]

100, 125, 160, 200, 250, 315, 400
 
6 Accessories

No entry: without accessories
D2Double lip seal both ends
G2 Matching flanges for both ends
 
7 Attachments (control components)
For example
BC0 Compact controller
XD4Universal controller (VARYCONTROL)

8 Equipment function
Room control
RS Supply air controller (Room Supply)
RE Extract air controller (Room Extract).

 
9 Operating mode
F Room master for single controller, constant setpoint value

M Room master for single controller, variable setpoint value
Slave controller (only with room solutions)

 
10 Signal voltage range
For the actual and setpoint value signals
00 – 10 V DC
2 2 – 10 V DC
 
11 Expansion modules

Option 1: Power supply
No entry: 24 V AC/DC
T With EM-TRF for 230 V AC mains supply
U With EM-TRF-USV (including battery pack for uninterruptible 230 V AC power supply (UPS)

Option 2: Digital communication interface
No entry: without communication interface
B With EM-BAC-MOD for VACnet MS/TP
M With EM-BAC-MOD for Modbus RTU
I With EM-IP for BACnet IP, Modbus IP and web server
R With EM-IP (including real time clock, RTC) for BACnet IP, Modbus IP and web server

Option 3: Automatic zero point correction
No entry: no zero point correction
Z With EM-AUTOZERO solenoid valve for automatic zero point correction

12 Operating values for factory setting
Volume flow rate [m³/h or l/s]

For operating mode F
qᵥconst: constant volume flow rate1, 2

Other parameters are only relevant for the room master as part
of a room solution3; for single controllers enter 0
qᵥconst_sup: constant supply air (room value)
qᵥconst_ext: constant extract air (room value)
qᵥdiff: supply air/extract air difference (room value)

For operating mode M
qᵥmin: minimum volume flow rate1, 2
qᵥmax: maximum volume flow rate1, 2

Other parameters are only relevant for the room master as part
of a room solution3; for single controllers enter 0
qᵥconst_sup: constant supply air (room value)
qᵥconst_ext: constant extract air (room value)
qᵥdiff: supply air/extract air difference (room value)

For operating mode S
No parameters are required for the slave controller; all entries
have to be made on the room master

For volume flow rate operating values please note:
1 Single controller: qᵥmin, qᵥmax or qᵥconst apply to the controller
2 Room solutions: qᵥmin, qᵥmax, qᵥconst apply to the room
3 For more information on room solutions with several TROX
UNIVERSAL controllers connected with plug and play and for
order examples please refer to the product datasheet

 
13 Damper blade position
Only with spring return actuators
NO Power off to open (Normally Open)
NC  Power off to close (Normally Closed)

Usefull additions
Optional room control panel
BE-LCD with 40-character display

Order example: TVR/200/XD4/V2/500–1200 m³/h/NO
TypeTVR
Acoustic claddingWithout acoustic cladding
MaterialGalvanised sheet steel
Duct connectionPush-fit, suitable for ducts according to EN 1506, with groove for optional lip seal
Nominal size200
AccessoriesWithout accessories
Attachments (control components)VARYCONTROL Universal controller; static transducer; analogue control; safe position with spring return
Operating modeVariable operation
Signal voltage range2 – 10 V DC
Volume flow rate500 – 1200 [m³/h]
Damper blade positionPower off to open (Normally/ Open)

,
Order code for volume flow control (with TROX UNIVERSAL attachment)
TVRDA2FL / 160 / G2 / TUNF / RS / M / 0 / UMZ / / NC
12345678910111213

1 Type

TVR VAV terminal unit 

2 Acoustic cladding
No entry required: None
D With acoustic cladding 

3 Material
No entry: galvanised sheet steel
P1 Powder-coated RAL 7001, silver grey
A2 Stainless steel construction 

4 Duct connection
No entry: push-fit, suitable for ducts according to EN
1506; with groove for optional lip seal
FL Flange both ends (not for TVR-D-P1) 

5 Nominal size [mm]
100, 125, 160, 200, 250, 315, 400 

6 Accessories
No entry required: None
D2 Double lip seal both sides
G2 Matching flanges both sides 

7 Attachments (control components)
TROX UNIVERSAL controller with
TUN Actuator (150 s)
TUNF Spring return actuator (150 s)
TUS Fast-running actuator (3 s)
TUSD Fast-running actuator (3 s), with digital communication interface (TROX HPD) 

8 Equipment function
Room control
RS Supply air control (Room Supply)
RE  Extract air control (Room Extract) 

9 Volume flow rate setting
M Master (RMF function)S Slave
F Constant flow rate controller 

10 Signal voltage range
0 0 – 10 V DC
2 2 – 10 V DC 

11 Expansion of attachments
Option 1: Power supply
No entry required: 24 V AC/DC
T EM-TRF for 230 V AC
U EM-TRF-USV for 230 V 
AC, provides uninterruptible power supply (UPS) 
Option 2: Digital communication interface
No entry required: None
B
EM-BAC-MOD-01 for BACnet MS/TP
M EM-BAC-MOD-01 for Modbus RTU
I EM-IP: EM-IP for BACnet/IP, Modbus/IP and web server
R EM-IP with real time clock 
Option 3: Automatic zero point correction
No entry required: None
Z EM-AUTOZERO with solenoid valve 

12 Operating values [m³/h or l/s] Master (RMF function)qᵥmin: minimum volume flow rateqᵥmax: maximum volume flow rateqᵥconst_Supply air: constant supply airqᵥconst_Extract air: constant extract airqᵥDiff: Supply air/extract air difference Constant valueqᵥconst: constant volume flow rate SlaveNo entry required 

13 Damper blade position
Only spring return actuators
NO Power off to OPEN
NC Power off to CLOSE 

Useful additions
Room control panel
BE-LCD 40-character display


 Order example: TVR-FL/250/TUNF/RE/M0/306-2205-0-0-0 [m³/h] /NC
TypeTVR
Acoustic claddingWithout acoustic cladding
MaterialGalvanised sheet steel
Duct connectionFlanges on both ends
Nominal size [mm]250
AccessoriesWithout accessories
Attachments (control components)TROX UNIVERSAL controller with spring return actuator (150s)
Equipment functionExtract air controller (Room Extract)
Operating modeRoom master or single controller, variable setpoint value
Signal voltage range0 – 10 V DC
Expansion modules24 V AC/DC supply, without digital communication interface, without automatic zero point correction
Operating values for factory settingqvmin = 306 m³/h
qvmax = 2205 m³/h
Damper blade positionPower off to close (Normally Closed)


Order code for differential pressure control (with VARYCONTROL attachment)
TVRDA2FL/160/G2/XF4/PDS/V/0/300-500 [Pa]/NO
123456789101112
1 Type
TVRVAV terminal unit
 
2 Acoustic cladding
No entry: none
D With acoustic cladding
 
3 Material
No entry: galvanised sheet steel
P1Powder-coated RAL 7001 (silver grey)
A2Stainless steel construction
 
4 Duct connection
No entry: push-fit, suitable for ducts according to EN 1506; with groove for optional lip seal
FLFlanges both ends (not for TVR-D-P1)
 
5 Nominal size [mm]
100, 125, 160, 200, 250, 315, 400
 
6 Accessories
No entry: without accessories
D2Double lip seal both ends
G2Matching flanges for both ends
 
7 Attachments (control components)
For example
XF0Compact controller for duct pressure
XF4Universal controller for duct pressure (VARYCONTROL)
 
8 Equipment function/Installation location
PDSDuct pressure controller – supply air (Pressure Duct Supply)
PDEDuct pressure controller – extract air (Pressure Duct Extract)
PRSRoom pressure controller – supply air (Pressure Room Supply)
PRERoom pressure controller – extract air (Pressure Room Extract)
 
9 Operating mode
FConstant value mode, one setpoint value (no externals switch conact)
V  Variable operation (adjustable setpoint value range)
 
10 Signal voltage range
For the actual and setpoint value signals
00 – 10 V DC
22 – 10 V DC
 
11 Operating values for factory setting
Differential pressure [Pa]

For duct pressure control, enter the differential pressure [Pa] as an absolute value

pconst(with operating mode F)
pmin – ∆pmax  (with operating mode V)
 
12 Damper blade position
Only with spring return actuators
NO Power off to open (Normally Open)
NC Power off to close (Normally closed)
Order example 1: TVR-FL/250/G2/XF4/PDS/F0/450 [Pa]/NC
TypeTVR
Acoustic claddingWithout acoustic cladding
MaterialGalvanised sheet steel
Duct connectionFlanges on both ends
Nominal size [mm]250
AccessoriesMatching flanges for both ends
Attachments (control components)VARYCONTROL Universal controller for duct pressure; analogue interface
Equipment functionDuct pressure control, supply air (Pressure Duct Supply)
Operating modeConstant value mode
Signal voltage range0 – 10 V DC
Operating value450 [Pa]
Damper blade positionPower off to close (Normally Closed)

,
Order code for differential pressure control (with TROX UNIVERSAL controller as attachment)
TVRDFL / 160 / G2 / TUNF / PRS / MFP / 0 / UMZ / / NC
12345678910

1 Type
TVZ 
VAV terminal unit, supply air 
2 Acoustic cladding
No entry required: None

D With acoustic cladding 

3 Nominal size [mm]
125160200250315400 

4 AccessoriesNo entry required: None
D1 Double lip seal 

5 Attachments (control components)
For example
XF0 Compact controller for duct pressure
XF4 Universal controller for duct pressure (VARYCONTROL) 

6 Equipment function/installation location
PDS Duct pressure control, supply air
PRS Room pressure control, supply air 

7 Operating mode
F Constant value (a setpoint value)
V Variable (setpoint value range) 

8 Signal voltage range
For the actual and setpoint value signals
0 0 – 10 V DC
2 2 – 10 V DC 

9 Operating values for factory setting
Differential pressure [Pa]
For duct pressure control, enter the differential pressure [Pa] as an absolute value 
Δpconst (in operating mode F)
Δpmin – Δpmax (in operating mode V) 

10 Damper blade position
Only spring return actuators
NO Power off to OPEN
NC Power off to CLOSE


Order example: TVZ/160/D1/XF4/PDS/F/2/470 Pa/NO
Nominal size160 mm
AccessoriesDouble lip seal (one end)
Attachments (control components)VARYCONTROL Universal controller for duct pressure
Equipment functionDuct pressure control, supply air
Operating modeConstant value
Signal voltage range2 – 10 V DC
Operating value470 Pa
Damper blade positionPower off to OPEN
 
,
Order code for differential pressure control (with TROX UNIVERSAL attachment)
TVZD / 160 / D1 / TUNF / PRS /MFP /0 / UMZ / / NC
1234567891011

1 Type
TVZ 
VAV terminal unit, supply air 

2 Acoustic cladding
No entry required: None
D With acoustic cladding 

3 Nominal size [mm]
125160200250315400 

4 Accessories
No entry required: None
D1 Double lip seal 

5 Attachments (control components)
TROX UNIVERSAL controller with
TUN Actuator (150 s)
TUNF Spring return actuator (150 s)
TUS Fast-running actuator (3 s)
TUSD Fast-running actuator (3 s), with digital communication interface (TROX HPD) 

6 Equipment functionY
Pressure control
PRS Room pressure control, supply air
PDS Duct pressure control, supply air 

7 Differential pressure setting
MFP Master, constant pressure control
MVP Master, variable differential pressure control
SFP Slave, constant pressure control
SVP Slave, variable differential pressure control 

8 Signal voltage range
0 0 - 10 V DC
2 2 - 10 V DC 

9 Expansion modules
Option 1: Power supply
No entry required: 24 V AC/DC
T EM-TRF for 230 V AC
U EM-TRF-USV for 230 V AC, provides uninterruptible power supply (UPS) 
Option 2: Digital communication interface
No entry required: None
B
EM-BAC-MOD-01 for BACnet MS/TP
M EM-BAC-MOD-01 for Modbus RTU
I EM-IP for BACnet/IP, Modbus/IP and web server
R EM-IP with real time clock 
Option 3: Volume flow rate measurement
No entry required: None
V  EM-V Volume flow rate measurement for differential pressure control 
Option 4: Automatic zero point correction
No entry required: None
Z EM-AUTOZERO solenoid valve (only with V) 

10 Operating values for factory setting
Pressure [Pa], volume flow rate [m³/h or l/s]
Slave SVP
Δpmin: minimum differential pressure
Δpmax: maximum differential pressure Slave SFP
Δpconst: Constant differential pressure Master MFP and MVP like Slave, but additionally
qᵥmin: minimum volume flow rate
qᵥmax: maximum volume flow rate
qᵥconst_CLOSED: constant supply air
qᵥconst_Exhaust: constant extract air
qᵥDiff: Supply air/extract air difference 

11 Damper blade position
Only spring return actuators
NO Power off to OPEN
NC Power off to CLOSE 
Useful additions Room control panel
BE-LCD 40-character display 
The differential pressure transducer required for room or duct pressure control has to be ordered separately, e.g.
PT-699 for room pressure control
PT-699-DUCT for duct pressure control, including tube and pressure tap 


Order example: TVZ/200/TUS/PRS/MVP/0/B/-10/-60/ 600/1250/ 0/ 0/-100

Nominal size200 mm
Attachments (control components)TROX UNIVERSAL controller, fast-running actuator (3 s)
Equipment functionRoom pressure control, supply air
Differential pressure settingMaster, variable differential pressure control
Signal voltage range0 – 10 V DC
Expansion moduleswith expansion module EM-BAC-MODBACnet MS/TP interface card
Operating valuesΔpmin = -10 Pa, Δpmax = -60 Paqᵥmin = 600 m³/h,qᵥmax = 1250 m³/hqᵥconst_Supply air = 0 m³/h, qᵥconst_Extract air = 0 m³/hqᵥDiff = - 100 m³/h
 
,
Order code for room control (with EASYLAB attachment)
TVZD/160/D1/ELAB/S/RS/UMZ/LAB/
123456791011

1 Type
TVZ
VAV terminal unit, supply air 
2 Acoustic cladding
No entry required: None
D With acoustic cladding 

3 Nominal size [mm]
125160200250315400 

4 Accessories
No entry required: None
D1 Double lip seal

 5 Attachments (control components)
ELAB EASYLAB controller TCU3 

6 Actuators
S Fast-running actuator (3 s)
SD Fast-running actuator (3 s), with digital communication interface (TROX HPD) 

7 Equipment function Room control
RS Supply air control (Room Supply)
PC Differential pressure control (Pressure Control) 

9 Expansion modules
Option 1: Power supply
No entry required: 24 V AC/DC
T EM-TRF for 230 V AC
U EM-TRF-USV for 230 V AC, provides uninterruptible power supply (UPS) 
Option 2: Digital communication interface
No entry required: None
B
EM-BAC-MOD-01 for BACnet MS/TP
M EM-BAC-MOD-01 for Modbus RTU
I EM-IP for BACnet/IP, Modbus/IP and web server
R EM-IP with real time clock 
Option 3: Automatic zero point correction
No entry required: None
Z EM-AUTOZERO
Solenoid valve for automatic zero point correction 

10 Additional functions
Without room management function
LAB Extract air led system (laboratories)
CLR Supply air led system (clean rooms) 
With room management function
LAB-RMF Extract air led system
CLR-RMF Supply air led system 

11 Operating values for factory setting
(only required when room management function is active) 
Volume flow rate [m³/h or l/s], pressure [Pa] 
Total extract air/supply air of room:
qv1: Standard mode
qv2: reduced operation
qv3: increased operation
qv4: constant supply air
qv5: constant extract air
qv6: Supply air/extract air difference
ΔpSet: Setpoint pressure (only with differential pressure control) 
Useful additions
Room control panel (only for devices with RMF)
BE-LCD 40-character display 
The differential pressure transducer required for room pressure control (equipment function) has to be ordered separately, e.g.
PT-699 Measuring range ±50 Pa or ±100 Pa
PT-GB604 Measuring range ±100 Pa


Order example: TVZ/200/ELAB/SD/RS/CLR-RMF/3500/1000/5000/250/0/-150
Acoustic claddingwithout
Nominal size200 mm
Attachments (control components)EASYLAB controller TCU3 with fast-running actuator (3 s)
ActuatorFast-running actuator (3 s), with digital communication interface
Equipment functionSupply air control (Room Supply)
Additional functionSupply air led system with room management function
Operating valuesqv1 = 3500 m³/hqv2 = 1000 m³/hqv3 = 5000 m³/hqv4 = 250 m³/hqv5 = 0qv6 = -150 m³/h


Order code for single operation (with EASYLAB attachment)
TVZD/160/D1/ELAB/S/SCE0/UMZ/

Valvula vav/

vruksho vavo paryavaran bachao

12345678910111213

1 Type

TVR VAV terminal unit 

2 Acoustic cladding
No entry required: None
D With acoustic cladding 

3 Material
No entry: galvanised sheet steel
P1 Powder-coated RAL 7001, silver grey
A2 Stainless steel construction 

4 Duct connection
No entry: push-fit, suitable for ducts according to EN
1506; with groove for optional lip seal
FL Flange both ends (not for TVR-D-P1) 

5 Nominal size [mm]
100, 125, 160, 200, 250, 315, 400 

6 Accessories
No entry required: None
D2 Double lip seal both sides
G2 Matching flanges both sides 

7 Attachments (control components)
TROX UNIVERSAL controller with
TUN Actuator (150 s)
TUNF Spring return actuator (150 s)
TUS Fast-running actuator (3 s)
TUSD Fast-running actuator (3 s), with digital communication interface (TROX HPD) 

8 Equipment function
Room control
RS Supply air control (Room Supply)
RE  Extract air control (Room Extract) 

9 Volume flow rate setting
M Master (RMF function)S Slave
F Constant flow rate controller 

10 Signal voltage range
0 0 – 10 V DC
2 2 – 10 V DC 

11 Expansion of attachments
Option 1: Power supply
No entry required: 24 V AC/DC
T EM-TRF for 230 V AC
U EM-TRF-USV for 230 V 
AC, provides uninterruptible power supply (UPS) 
Option 2: Digital communication interface
No entry required: None
B
EM-BAC-MOD-01 for BACnet MS/TP
M EM-BAC-MOD-01 for Modbus RTU
I EM-IP: EM-IP for BACnet/IP, Modbus/IP and web server
R EM-IP with real time clock 
Option 3: Automatic zero point correction
No entry required: None
Z EM-AUTOZERO with solenoid valve 

12 Operating values [m³/h or l/s] Master (RMF function)qᵥmin: minimum volume flow rateqᵥmax: maximum volume flow rateqᵥconst_Supply air: constant supply airqᵥconst_Extract air: constant extract airqᵥDiff: Supply air/extract air difference Constant valueqᵥconst: constant volume flow rate SlaveNo entry required 

13 Damper blade position
Only spring return actuators
NO Power off to OPEN
NC Power off to CLOSE 

Useful additions
Room control panel
BE-LCD 40-character display


 Order example: TVR-FL/250/TUNF/RE/M0/306-2205-0-0-0 [m³/h] /NC
TypeTVR
Acoustic claddingWithout acoustic cladding
MaterialGalvanised sheet steel
Duct connectionFlanges on both ends
Nominal size [mm]250
AccessoriesWithout accessories
Attachments (control components)TROX UNIVERSAL controller with spring return actuator (150s)
Equipment functionExtract air controller (Room Extract)
Operating modeRoom master or single controller, variable setpoint value
Signal voltage range0 – 10 V DC
Expansion modules24 V AC/DC supply, without digital communication interface, without automatic zero point correction
Operating values for factory settingqvmin = 306 m³/h
qvmax = 2205 m³/h
Damper blade positionPower off to close (Normally Closed)


Order code for differential pressure control (with VARYCONTROL attachment)
TVRDA2FL/160/G2/XF4/PDS/V/0/300-500 [Pa]/NO
123456789101112
1 Type
TVRVAV terminal unit
 
2 Acoustic cladding
No entry: none
D With acoustic cladding
 
3 Material
No entry: galvanised sheet steel
P1Powder-coated RAL 7001 (silver grey)
A2Stainless steel construction
 
4 Duct connection
No entry: push-fit, suitable for ducts according to EN 1506; with groove for optional lip seal
FLFlanges both ends (not for TVR-D-P1)
 
5 Nominal size [mm]
100, 125, 160, 200, 250, 315, 400
 
6 Accessories
No entry: without accessories
D2Double lip seal both ends
G2Matching flanges for both ends
 
7 Attachments (control components)
For example
XF0Compact controller for duct pressure
XF4Universal controller for duct pressure (VARYCONTROL)
 
8 Equipment function/Installation location
PDSDuct pressure controller – supply air (Pressure Duct Supply)
PDEDuct pressure controller – extract air (Pressure Duct Extract)
PRSRoom pressure controller – supply air (Pressure Room Supply)
PRERoom pressure controller – extract air (Pressure Room Extract)
 
9 Operating mode
FConstant value mode, one setpoint value (no externals switch conact)
V  Variable operation (adjustable setpoint value range)
 
10 Signal voltage range
For the actual and setpoint value signals
00 – 10 V DC
22 – 10 V DC
 
11 Operating values for factory setting
Differential pressure [Pa]

For duct pressure control, enter the differential pressure [Pa] as an absolute value

pconst(with operating mode F)
pmin – ∆pmax  (with operating mode V)
 
12 Damper blade position
Only with spring return actuators
NO Power off to open (Normally Open)
NC Power off to close (Normally closed)
Order example 1: TVR-FL/250/G2/XF4/PDS/F0/450 [Pa]/NC
TypeTVR
Acoustic claddingWithout acoustic cladding
MaterialGalvanised sheet steel
Duct connectionFlanges on both ends
Nominal size [mm]250
AccessoriesMatching flanges for both ends
Attachments (control components)VARYCONTROL Universal controller for duct pressure; analogue interface
Equipment functionDuct pressure control, supply air (Pressure Duct Supply)
Operating modeConstant value mode
Signal voltage range0 – 10 V DC
Operating value450 [Pa]
Damper blade positionPower off to close (Normally Closed)

,
Order code for differential pressure control (with TROX UNIVERSAL controller as attachment)
TVRDFL / 160 / G2 / TUNF / PRS / MFP / 0 / UMZ / / NC
12345678910111213

1 Type
TVRVAV terminal unit 

2 Acoustic cladding
No entry: none
D With acoustic cladding 

3 Material
No entry: galvanised sheet steel
P1 Powder-coated RAL 7001, silver grey
A2 Stainless steel construction 

4 Duct connection
No entry: push-fit, suitable for ducts according to EN 1506; with groove for optional lip seal
FL Flanges both ends (not for TVR-D-P1) 

5 Nominal size [mm]
100, 125, 160, 200, 250, 315, 400 

6 Accessories
No entry: without accessories
D2 Double lip seal both ends
G2 Matching flanges for both ends 

7 Attachments (control components)
TROX UNIVERSAL controller with
TUN  with actuator (150 s)
TUNF with spring return actuator (150 s)
TUS with fast-running actuator (3 s)
TUSD with fast-running actuator (3 s) and digital communication interface (TROX HPD) 

8 Equipment function
PDS Duct pressure controller – supply air (Pressure Duct Supply)
PDE Duct pressure controller – extract air (Pressure Duct Extract)
PRS Room pressure controller – supply air (Pressure Room Supply)
PRE Room pressure controller – extract air (Pressure Room Extract)

9 Differential pressure setting
MFP Room master or single controller, constant pressure setpoint value
MVP Room master or single controller, variable pressure setpoint value

With room solutions
SFP Slave, constant pressure setpoint
SVP Slave, variable pressuure setpoint

10 Signal voltage range
For the actual and setpint value signals
0 0 – 10 V DC
2 2 – 10 V DC 

11 Expansion modules
Option 1: Power supply
No entry required: 24 V AC/DC
T With EM-TRF for 230 V AC mains supply
U With EM-TRF-USV (including battery pack) for uninterruptible 230 V AC power supply (UPS) 

Option 2: Digital communication interface
No entry: without digital communication interface
B
 With EM-BAC-MOD-01 for BACnet MS/TP
M With EM-BAC-MOD-01 for Modbus RTU
I  With EM-IP: EM-IP for BACnet/IP, Modbus/IP and web server
R With EM-IP (including real time clock, RTC) for BACnet IP, Modbus IP and web server

Option 3: Volume flow rate measurement
No entry: without volume flow rate measurement
V  With EM-V for volume flow rate measurement with the differential pressure controller 

Option 4: Automatic zero point correction
No entry: no automatic zero pint correction
Z With EM-AUTOZERO solenoid valve for automatic zero pint correction (only togehter with EM-V) 

12 Operating values for factory setting
Volume flow rate[m³/h or l/s], pressure [Pa]

For operating mode MFP or SFP
Δpconst: Constant differential pressure 

For operating mode MVP or SVP
Δpmin: minimum differential pressure
Δpmax: maximum differential pressure

Other parameters for operating modes MFP and MVP
Only relevant for the room master as part of a room solution; for single controllers enter 0
qᵥmin: minimum volume flow rate (room value)
qᵥmax: maximum volume flow rate (room value)
qᵥconst_Supply air: constant supply air (room value)
qᵥconst_Extract air: constant extract air (room value)
qᵥDiff: Supply air/extract air difference (room value) 

Please note
For more information on room solutions with several TROX UNIVERSAL controllers connected with plug and play and for order examples please refer to the product datasheet

13 Damper blade position

Only with spring return actuators
NO Power off to open (Normally Open)
NC Power off to close (Normally Closed)


Useful additions
Differential pressure transducers required for room or duct pressure control have to be ordered separately or provided by others, e.g.
PT-699 Differential pressure transducer for room pressure control
PT-699-DUCT Differential pressure transducers for duct pressure control, including pressure measurement kit
Room control panel

Optional room control panel
BE-LCD
 40-character display 


Order example: TVR-D-FL/160/G2/TUNF/PRS/MFP/0/UMZ/250[Pa]/NC

TypeTVR
Acoustic claddingWithout acoustic cladding
MaterialGalvanised sheet steel
Duct connectionPush-fit, suitable for ducts according to EN 1506; with groove for optional lip seal
Nominal size [mm]160
AccessoriesMatching flanges for both ends
Attachments (control components)TROX UNIVERSAL controller with fast-running actuator, analogue interface
Equipment functionRoom pressure contoller - supply air (Pressure Room Supply)
Operating modeRoom master or single controller, constant pressure setpoint value
Signal voltage range0 – 10 V DC
Expansion modulesWith EM-TRF-USV (including battery pack) for uninterruptible 230 V AC power supply (UPS)
With EM-BAC-MOD for Modbus RTU
Without volume flow rate measurement
With EM-AUTOZERO solenoid valve for automatic zero pint correction
Damper blade position250 [Pa]
Operating values for factory settingPower off to close (Normally Closed)

,
Order code for room control (with EASYLAB attachment)
TVRDFL/160/G2/ELAB/S/RS/UMZ/LAB/
12345678910

1 Type
TVZ 
VAV terminal unit, supply air 
2 Acoustic cladding
No entry required: None

D With acoustic cladding 

3 Nominal size [mm]
125160200250315400 

4 AccessoriesNo entry required: None
D1 Double lip seal 

5 Attachments (control components)
For example
XF0 Compact controller for duct pressure
XF4 Universal controller for duct pressure (VARYCONTROL) 

6 Equipment function/installation location
PDS Duct pressure control, supply air
PRS Room pressure control, supply air 

7 Operating mode
F Constant value (a setpoint value)
V Variable (setpoint value range) 

8 Signal voltage range
For the actual and setpoint value signals
0 0 – 10 V DC
2 2 – 10 V DC 

9 Operating values for factory setting
Differential pressure [Pa]
For duct pressure control, enter the differential pressure [Pa] as an absolute value 
Δpconst (in operating mode F)
Δpmin – Δpmax (in operating mode V) 

10 Damper blade position
Only spring return actuators
NO Power off to OPEN
NC Power off to CLOSE


Order example: TVZ/160/D1/XF4/PDS/F/2/470 Pa/NO
Nominal size160 mm
AccessoriesDouble lip seal (one end)
Attachments (control components)VARYCONTROL Universal controller for duct pressure
Equipment functionDuct pressure control, supply air
Operating modeConstant value
Signal voltage range2 – 10 V DC
Operating value470 Pa
Damper blade positionPower off to OPEN
 
,
Order code for differential pressure control (with TROX UNIVERSAL attachment)
TVZD / 160 / D1 / TUNF / PRS /MFP /0 / UMZ / / NC
1234567891011

1 Type
TVZ 
VAV terminal unit, supply air 

2 Acoustic cladding
No entry required: None
D With acoustic cladding 

3 Nominal size [mm]
125160200250315400 

4 Accessories
No entry required: None
D1 Double lip seal 

5 Attachments (control components)
TROX UNIVERSAL controller with
TUN Actuator (150 s)
TUNF Spring return actuator (150 s)
TUS Fast-running actuator (3 s)
TUSD Fast-running actuator (3 s), with digital communication interface (TROX HPD) 

6 Equipment functionY
Pressure control
PRS Room pressure control, supply air
PDS Duct pressure control, supply air 

7 Differential pressure setting
MFP Master, constant pressure control
MVP Master, variable differential pressure control
SFP Slave, constant pressure control
SVP Slave, variable differential pressure control 

8 Signal voltage range
0 0 - 10 V DC
2 2 - 10 V DC 

9 Expansion modules
Option 1: Power supply
No entry required: 24 V AC/DC
T EM-TRF for 230 V AC
U EM-TRF-USV for 230 V AC, provides uninterruptible power supply (UPS) 
Option 2: Digital communication interface
No entry required: None
B
EM-BAC-MOD-01 for BACnet MS/TP
M EM-BAC-MOD-01 for Modbus RTU
I EM-IP for BACnet/IP, Modbus/IP and web server
R EM-IP with real time clock 
Option 3: Volume flow rate measurement
No entry required: None
V  EM-V Volume flow rate measurement for differential pressure control 
Option 4: Automatic zero point correction
No entry required: None
Z EM-AUTOZERO solenoid valve (only with V) 

10 Operating values for factory setting
Pressure [Pa], volume flow rate [m³/h or l/s]
Slave SVP
Δpmin: minimum differential pressure
Δpmax: maximum differential pressure Slave SFP
Δpconst: Constant differential pressure Master MFP and MVP like Slave, but additionally
qᵥmin: minimum volume flow rate
qᵥmax: maximum volume flow rate
qᵥconst_CLOSED: constant supply air
qᵥconst_Exhaust: constant extract air
qᵥDiff: Supply air/extract air difference 

11 Damper blade position
Only spring return actuators
NO Power off to OPEN
NC Power off to CLOSE 
Useful additions Room control panel
BE-LCD 40-character display 
The differential pressure transducer required for room or duct pressure control has to be ordered separately, e.g.
PT-699 for room pressure control
PT-699-DUCT for duct pressure control, including tube and pressure tap 


Order example: TVZ/200/TUS/PRS/MVP/0/B/-10/-60/ 600/1250/ 0/ 0/-100

Nominal size200 mm
Attachments (control components)TROX UNIVERSAL controller, fast-running actuator (3 s)
Equipment functionRoom pressure control, supply air
Differential pressure settingMaster, variable differential pressure control
Signal voltage range0 – 10 V DC
Expansion moduleswith expansion module EM-BAC-MODBACnet MS/TP interface card
Operating valuesΔpmin = -10 Pa, Δpmax = -60 Paqᵥmin = 600 m³/h,qᵥmax = 1250 m³/hqᵥconst_Supply air = 0 m³/h, qᵥconst_Extract air = 0 m³/hqᵥDiff = - 100 m³/h
 
,
Order code for room control (with EASYLAB attachment)
TVZD/160/D1/ELAB/S/RS/UMZ/LAB/
123456791011

1 Type
TVZ
VAV terminal unit, supply air 
2 Acoustic cladding
No entry required: None
D With acoustic cladding 

3 Nominal size [mm]
125160200250315400 

4 Accessories
No entry required: None
D1 Double lip seal

 5 Attachments (control components)
ELAB EASYLAB controller TCU3 

6 Actuators
S Fast-running actuator (3 s)
SD Fast-running actuator (3 s), with digital communication interface (TROX HPD) 

7 Equipment function Room control
RS Supply air control (Room Supply)
PC Differential pressure control (Pressure Control) 

9 Expansion modules
Option 1: Power supply
No entry required: 24 V AC/DC
T EM-TRF for 230 V AC
U EM-TRF-USV for 230 V AC, provides uninterruptible power supply (UPS) 
Option 2: Digital communication interface
No entry required: None
B
EM-BAC-MOD-01 for BACnet MS/TP
M EM-BAC-MOD-01 for Modbus RTU
I EM-IP for BACnet/IP, Modbus/IP and web server
R EM-IP with real time clock 
Option 3: Automatic zero point correction
No entry required: None
Z EM-AUTOZERO
Solenoid valve for automatic zero point correction 

10 Additional functions
Without room management function
LAB Extract air led system (laboratories)
CLR Supply air led system (clean rooms) 
With room management function
LAB-RMF Extract air led system
CLR-RMF Supply air led system 

11 Operating values for factory setting
(only required when room management function is active) 
Volume flow rate [m³/h or l/s], pressure [Pa] 
Total extract air/supply air of room:
qv1: Standard mode
qv2: reduced operation
qv3: increased operation
qv4: constant supply air
qv5: constant extract air
qv6: Supply air/extract air difference
ΔpSet: Setpoint pressure (only with differential pressure control) 
Useful additions
Room control panel (only for devices with RMF)
BE-LCD 40-character display 
The differential pressure transducer required for room pressure control (equipment function) has to be ordered separately, e.g.
PT-699 Measuring range ±50 Pa or ±100 Pa
PT-GB604 Measuring range ±100 Pa


Order example: TVZ/200/ELAB/SD/RS/CLR-RMF/3500/1000/5000/250/0/-150
Acoustic claddingwithout
Nominal size200 mm
Attachments (control components)EASYLAB controller TCU3 with fast-running actuator (3 s)
ActuatorFast-running actuator (3 s), with digital communication interface
Equipment functionSupply air control (Room Supply)
Additional functionSupply air led system with room management function
Operating valuesqv1 = 3500 m³/hqv2 = 1000 m³/hqv3 = 5000 m³/hqv4 = 250 m³/hqv5 = 0qv6 = -150 m³/h


Order code for single operation (with EASYLAB attachment)
TVZD/160/D1/ELAB/S/SCE0/UMZ/